+ | === July 10th 2012 === | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | | Run | time | run conditions | comments | | ||
+ | | 760 | 12:30 | pedestals| ch 0,1,2 with PMTs| | ||
+ | | 761 | 12:40 | LED | HV on | | ||
+ | | 762 | 13:00 | LED | HV on, change timing| | ||
+ | | 763 | 18:35 | electrons | ||
+ | | 764 | 19:15 | electrons | ||
+ | | 765 | 19:45 | electrons | ||
+ | | 766 | 19:57 | electrons | ||
+ | | 767 | 19:57 | electrons | ||
+ | | 768 | 19:57 | electrons | ||
+ | | 769 | 20:21 | electrons | ||
+ | | 771-781 | 22:31 |problems after powercut| trigger timing changed | | ||
+ | | 782 | 0:21 |electrons in chamber|HV 500V, all light tight, dt=50, B=0 | | ||
+ | | 783 | 0:21 |electrons in chamber|HV 500V, all light tight, dt=50, B=0.45| | ||
+ | |||
+ | === July 11th 2012 === | ||
+ | |||
+ | HW changes: | ||
+ | 1) the second stage of the dual timer has been replaced by a Stanford for reliable and reproducible setting. | ||
+ | 2) all five channels have been equipped with PMT+Electronics | ||
+ | 3) the chamber of the spectrometer has been connected with the interaction region (i.e. the glass window removed) | ||
+ | 4) a lead collimator has been inserted between the gas jet and the spectrometer | ||
+ | | ||
+ | Plan of the day: | ||
+ | A) scan in integration time to find the best timing [with small magnet in] | ||
+ | B) scan in HV to equalize gains [with small magnet in] | ||
+ | C) spectrum with B=0 and B>0 (with small magnet out, having subtracted the common background) | ||
+ | | ||
+ | | ||
+ | |||
+ | |Run | time | run conditions | comments | | ||
+ | |789 | 15:47 |No Beam HV on ch 0-4 500 V | pedestals| | ||
+ | |790 | 16:22 |No Beam HV on ch 0-4 900 V | pedestals| | ||
+ | |793 | 16:22 |electrons | ||
+ | |794-797| 17-18| Trigger Test|the trigger doesn' | ||
+ | |798| 19:38|T (signal splitting) removed from trigger |the trigger works| | ||
+ | |799|19: | ||
+ | |800|20:00| HV=0, laser+plasma, | ||
+ | |801|20:04| try HV=500 but impossible to take data| | ||
+ | |804|22:50| HV=700 PMT 0, HV=0 PMT 1-4|saturation on PMT 0| | ||
+ | |805|22:52| HV=600 PMT 0 1 2, HV=0 PMT 3 4|now verify that noise on PMT0 increases with num of connected cards| | ||
+ | |806|23:26| HV=600 PMT 0 1 2, HV=0 PMT 3 4|only card 1 is connected, with the attenuator| | ||
+ | |807|23:36| HV=600 PMT 0 1 2, HV=0 PMT 3 4| B=0.45T| | ||
+ | |808|23:47| HV=600 PMT 0 1 2, HV=0 PMT 3 4| B=0.45T, card 1 2 3 are connected with attenuators| | ||
+ | |809-814| 23: | ||
+ | |816-821| 24: | ||
+ | |822|24: | ||
+ | |823|24: | ||
+ | |824|24: | ||
+ | |825|24: | ||
+ | |826|24: | ||
+ | |827|24: | ||
+ | |||
+ | === July 12th 2012 === | ||
+ | Investigated noise problem. Disappears by using screened cable for DY12 | ||
+ | |||
+ | |Run | time | run conditions | comments | | ||
+ | | 829|13:29 |hv 800 ch 0,1,2 |B=0 | | ||
+ | | 830|13:32 |hv 900 ch 0,1,2 |B=0 | | ||
+ | | 831|13:35 |hv 800 ch 0,1,2 | B=0 magnete flame in| | ||
+ | | 832|14: | ||
+ | | 833|14: | ||
+ | | 834-852|15: | ||
+ | | 853-858|16: | ||
+ | | 859-870|16: | ||
+ | | 871-872|17: | ||
+ | | 873 | B>0| turn on magnet. Hv default.| Elettroni deviati!!!| | ||
+ | | 874 | B>0 | magnet ON. HV default | costanti di calibrazione Offline C=(1.2, | ||
+ | | 875 | B>0 | HV def | Collimatore: | ||
+ | | 876 | B=0 | HV def | Collimatore; | ||
+ | | 877 | B=0 | HV def | Collimatore | | ||
+ | | 878 | B=0 | HV def | Collimatore | | ||
+ | | 879 | B=0 | HV def | Collimatore chiuso; scambiati canali 3 e 4 che erano invertiti; C=(1.2, | ||
+ | | 882 | B=0 | HV def | Collimatore chiuso | | ||
+ | | 883 | B=0 | HV def | Collimatore chiuso; Flame Magnet IN; Use for Ped File | | ||
+ | | 884 | B=0 | HV def | Collimatore aperto 2mm; Flame Magnet OUT; usb problem at the end| | ||
+ | | 885 | B=0 | HV def | Collimatore aperto 2mm; Flame Magnet OUT| | ||
+ | | 886 | B=0 | HV def | Collimatore aperto 1cm; Flame Magnet OUT| | ||
+ | | 887 | B=0.5 T | HV def | Collimatore aperto 1cm; Flame Magnet OUT| | ||
+ | === July 13th 2012 === | ||
+ | |||
+ | Debug of spectrometer trigger. Problems with upper part of logic unit, replaced with lower part. Dual timer removed, veto implemented with Stanford D signal set to 500 mus. Delay and width of trigger button revised, set to 500 mus. Missing alignment with photocatode. | ||
+ | |||
+ | |||
+ | === July 18th 2012 === | ||
+ | Pedestal studies | ||
+ | |||
+ | | 896 | 12:21| HV off| Only maroc 0 board+cable; | ||
+ | | 897 | 12:26| HV off| Only maroc 0 board+cable; | ||
+ | | 899 | 12:26| HV off| Only maroc 0 board no cable; no laser; improved trigger cable| RMS 1.5 cts | | ||
+ | |||
+ | Giulietto Felici works on electronics to improve grounding and box. | ||
+ | |||
+ | === July 25th 2012 === | ||
+ | |||
+ | test electronics with new shielding | ||
+ | |||
+ | | 900 | 10:37| pedestals| 5cards but no cables; RMS 1-2 ADC| | ||
+ | | 901 | 10:40| pedestals| 5cards cable #0 in; HV off; RMS ~6 for first 43 channels, 10-18 for the others | | ||
+ | | 902 | 10:44| pedestals| 5cards cable #0 in; HV=900V; RMS ~6 for first 43 channels, 10-18 for the others | | ||
+ | | 903 | 10:52| LED run| 5cards cable #0 in; HV=900V | | ||
+ | | 904 | 14:26| pedestals| 5cards all cables in; HV=0V | | ||
+ | | 905 | 14:29| pedestals| 5cards all cables in; HV=default | | ||
+ | | 905 | 14:29| pedestals| 5cards all cables in; HV=default -- high stat | | ||