July 10th 2012

Run time run conditions comments
760 12:30 pedestals ch 0,1,2 with PMTs
761 12:40 LED HV on
762 13:00 LED HV on, change timing
763 18:35 electrons but not to chamber HV 900V
764 19:15 electrons but not to chamber HV 500V
765 19:45 electrons but not to chamber HV 500V, ch0 light tight, flanges darkened
766 19:57 electrons but not to chamber HV 500V, ch0 light tight
767 19:57 electrons but not to chamber HV 500V, ch0 light tight, dt=150
768 19:57 electrons but not to chamber HV 500V, ch0 light tight, dt=250
769 20:21 electrons but not to chamber HV 500V, ch0 light tight, dt=50, magnet on
771-781 22:31 problems after powercut trigger timing changed
782 0:21 electrons in chamberHV 500V, all light tight, dt=50, B=0
783 0:21 electrons in chamberHV 500V, all light tight, dt=50, B=0.45

July 11th 2012

HW changes:

1) the second stage of the dual timer has been replaced by a Stanford for reliable and reproducible setting.
2) all five channels have been equipped with PMT+Electronics
3) the chamber of the spectrometer has been connected with the interaction region (i.e. the glass window removed)
4) a lead collimator has been inserted between the gas jet and the spectrometer

Plan of the day:

A) scan in integration time to find the best timing [with small magnet in]
B) scan in HV to equalize gains [with small magnet in]
C) spectrum with B=0 and B>0 (with small magnet out, having subtracted the common background)
Run time run conditions comments
789 15:47 No Beam HV on ch 0-4 500 V pedestals
790 16:22 No Beam HV on ch 0-4 900 V pedestals
793 16:22 electrons HV=500V. EM Noise is Back!
794-797 17-18 Trigger Testthe trigger doesn't works
798 19:38T (signal splitting) removed from trigger the trigger works
79919:44HV = 0V, laser+plasmaElectronic noise
80020:00 HV=0, laser+plasma, reinforce grounding
80120:04 try HV=500 but impossible to take data
80422:50 HV=700 PMT 0, HV=0 PMT 1-4saturation on PMT 0
80522:52 HV=600 PMT 0 1 2, HV=0 PMT 3 4now verify that noise on PMT0 increases with num of connected cards
80623:26 HV=600 PMT 0 1 2, HV=0 PMT 3 4only card 1 is connected, with the attenuator
80723:36 HV=600 PMT 0 1 2, HV=0 PMT 3 4 B=0.45T
80823:47 HV=600 PMT 0 1 2, HV=0 PMT 3 4 B=0.45T, card 1 2 3 are connected with attenuators
809-814 23:59HV=600 PMT 0 1 2, HV=0 PMT 3 4 B=0, scan in time reveals that t=0 is the best –>anticipate trigger
816-821 24:10HV=600 PMT 0 1 2, HV=0 PMT 3 4 B=0, scan in time: best timing dt = 100 ns
82224:27HV=550 V PMT 0, HV=600 PMT 1 2, HV=0 PMT 3 4 B=0
82324:30HV=550 V PMT 0, HV=600 PMT 1 2, HV=0 PMT 3 4 B=0
82424:37HV=500 V PMT 0, HV=600 PMT 1 2, HV=0 PMT 3 4 B=0
82524:37HV=OFF B=0
82624:41HV=900 PMT 0 1 2 B=0
82724:45HV=900 PMT 0 1 2, dt=0 B=0

July 12th 2012

Investigated noise problem. Disappears by using screened cable for DY12

Run time run conditions comments
82913:29 hv 800 ch 0,1,2 B=0
83013:32 hv 900 ch 0,1,2 B=0
83113:35 hv 800 ch 0,1,2 B=0 magnete flame in
83214:10 hv 500 ch 0,1,2 B=0 magnete flame in remove attenuators
83314:15 hv 600 ch 0,1,2 B=0 magnete flame in remove attenuators
834-85215:33 hv 600 ch 0-4 trigger problems
853-85816:40 hv 600 ch 0-4 time scan
859-87016:45 hv 500 ch 0-4 time scan
871-87217:30 HV scan to equalize establish that HV={580,550,500,480,480}. Found that last two cables are swapped
873 B>0 turn on magnet. Hv default. Elettroni deviati!!!
874 B>0 magnet ON. HV default costanti di calibrazione Offline C=(1.2,1,1.5,1.1,1.4)
875 B>0 HV def Collimatore: 2 blocchetti 5 cm Pb dopo la finestra con 2 mm separazione: 40 mrad * 100 cm –> dx=4 cm
876 B=0 HV def Collimatore; B ramping down?
877 B=0 HV def Collimatore
878 B=0 HV def Collimatore
879 B=0 HV def Collimatore chiuso; scambiati canali 3 e 4 che erano invertiti; C=(1.2,1,1.5,1.4,1.1)
882 B=0 HV def Collimatore chiuso
883 B=0 HV def Collimatore chiuso; Flame Magnet IN; Use for Ped File
884 B=0 HV def Collimatore aperto 2mm; Flame Magnet OUT; usb problem at the end
885 B=0 HV def Collimatore aperto 2mm; Flame Magnet OUT
886 B=0 HV def Collimatore aperto 1cm; Flame Magnet OUT
887 B=0.5 T HV def Collimatore aperto 1cm; Flame Magnet OUT

July 13th 2012

Debug of spectrometer trigger. Problems with upper part of logic unit, replaced with lower part. Dual timer removed, veto implemented with Stanford D signal set to 500 mus. Delay and width of trigger button revised, set to 500 mus. Missing alignment with photocatode.

July 18th 2012

Pedestal studies

896 12:21 HV off Only maroc 0 board+cable; no laser
897 12:26 HV off Only maroc 0 board+cable; no laser RMS 12 cts
899 12:26 HV off Only maroc 0 board no cable; no laser; improved trigger cable RMS 1.5 cts

Giulietto Felici works on electronics to improve grounding and box.

July 25th 2012

test electronics with new shielding

900 10:37 pedestals 5cards but no cables; RMS 1-2 ADC
901 10:40 pedestals 5cards cable #0 in; HV off; RMS ~6 for first 43 channels, 10-18 for the others
902 10:44 pedestals 5cards cable #0 in; HV=900V; RMS ~6 for first 43 channels, 10-18 for the others
903 10:52 LED run 5cards cable #0 in; HV=900V
904 14:26 pedestals 5cards all cables in; HV=0V
905 14:29 pedestals 5cards all cables in; HV=default
905 14:29 pedestals 5cards all cables in; HV=default – high stat