BTF Data Acquisition
HW Techs
BTFEH 1
This is the configuration on BTFEH1
VME Crate
- Ethernet VME_VMIC 7807
- 192.168.192.75 (dante075), MAC:00203801C8AB, SWBTFEH11, porta 36
- vnc on danteweb:5975,
- /u2/dcs/source_linux/standalone/btf_daq/trunk/DAQ_BTF_m5.2.vi
- SVMEE
- NIM crate
BTFEH1 ADDRESSES SVMEE
- QDC1 (profilemeter, Caen V792) = 0x000000
- QDC2 (Calorimeter, V965b) = 0xAA0000
- Scaler (SYS 3800) = 0xC08000
- PIO (I/O register, Caen V513) = F00000
BTFEH 2
This is the configuration on BTFEH2
VME Crate
- Ethernet VME_VMIC 7807
- 192.168.192.73 (dante073), MAC 002038015547,SWBTFEH23 porta 38
- vnc on danteweb:5973,
- /u2/dcs/source_linux/standalone/btf_daq/trunk/DAQ_BTFEH2_m5.2.vi
- SVMEE
- NIM crate
BTFEH2 ADDRESSES SVMEE
- QDC1 (profilemeter, Caen V792) = 0xAA0000
- QDC2 (Calorimeter, V965b) = 0xBB0000
- Scaler (SYS 3800) = 0x380000
- PIO (I/O register, Caen V513) = 00CC00
SVMEE
Standard VME Elements
- SYS 3800 - Scaler - Counting of this signals:
- Trigger from DDG- on CH30
- Acquired trigger - on CH31
- Caen V792 - QDC1 - Controlled elements:
- All channels are used
- Caen V513 - Digital I/O
- Used for BTF-DAQ control purposes (veto generation and distribuition)
- Caen V965 - QDC2 - Controlled elements:
- WCM1 - on CH0
- WCM2 - on CH1
- Calorimeter in BTF - CH7
- 2 X Caen V550 - Strip - Photon-tag - with hardware pedestal subtraction
- TDC
- Caen V556- PEAK Detector