 +====== Energetica Test stand page ======
 +
 +===== Software =====
 +
 +==== Acquisition ====
 +
 +CPU VME account: daq@151.100.44.118
 +
 +Software is on the 'VME CPU'.
 +  * Log in into the CPU
 +  * Go to CT directory
 +  * Customize the setup in main_acquisition.h
 +  * make clean
 +  * make acquire
 +  * acquire -n nevts -p freq -f output_file -z zero_suppression
 +
 +**The zero suppression is ENABLED by default.**
 +
 +The data/ directory is linked to the analizer software so probably you'd like to write the output there.
 +
 +=== Configuring the acquisition ===
 +
 +  * The modules that are acquired are specified in the main_acquisition.h file trough define statements:
 +<code cpp>
 +#define IOREG 1
 +#define TDC1190 1
 +#define TDCKLOE 0
 +#define WVD1721 1
 +#define WVD1724 0
 +#define ADC265 0
 +</code>
 +you need to **recompile** in order to apply your changes after modifying the main_acquisition.h file
 +
 +=== Stopping the acquisition ===
 +
 +The acquisition can be stopped at anny moment  by creating an **acq.stop** file in the directory where the acquisition is running.
 +<code>
 +enrg44:~/acq$ touch acq.stop
 +</code>
 +In this case the acq is stopped nicely after finishing the last trigger and automatically clean up the acq.stop file in order to be ready to restart again.
 +
 +
 +==== Module Software Description ====
 +
 +The addresses and the debug settings are in
 +  * wvd1724_lib.h
 +  * adc265_lib.h
 +  * ioreg_lib.h
 +  * tdc1190_lib.h
 +  * wvd1721_lib.h
 +The algorithm implementation is in
 +  * wvd1724_lib.c
 +  * adc265_lib.c
 +  * ioreg_lib.c
 +  * tdc1190_lib.c
 +  * wvd1721_lib.c
 +
 +=== TDC 1190 ===
 +
 +=== Wave Form digitizer ===
 +
 +
 +==== Analysis ====
 +
 +Software is on the laptop
 +  * Go to acq directory
 +
 +=== Data ===
 +
 +Data acquired can be found in the **data** directory that is a soft link to the VME disk.
 +
 +=== Configuration File ===
 +
 +The configuration file should be provided to Analizer trough the -con option
 +Analizer -con myconf.txt
 +Where the myconf.txt syntax can be seen in the conf_energ.txt file [please do not overwrite it! make your own copy and provide it to Analizer].
 +
  