 +======TIMING======
 +**Service to the user**
 +The user have a 2-channel arbitrary delay generator system {{:strutture:lnf:da:btf:dispositivi:dg535m.pdf|Stanford DG535m}}\\
 +remotely controlled in BTF control room with the respecive bypass in BTF Hall.
 +User customizable trigger signal (source LINAC SYS)
 +**{{:strutture:lnf:da:btf:dispositivi:dg535m.pdf|STANFORD Delay Generator DDG535m}}**
 +
 +__BTF Setup Menu (**BSM**)__\\
 +-> **Go Forever** = lets the DAFNE injection rejected pulses (till the Odoscope one) to be delivered at set frequency to BTF\\
 +-> **Single Shot** = only one pulse delivered to BTF, after the DAFNE injection pulses\\
 +\\
 +__General Timing Status (**GTS**)__\\
 +-> **Normal** = cutoff trigger signal @ BTF (the DHPTB101 still works!!!)\\
 +-> **BTF** = gives trigger signal @ BTF and implements BTF status setup (**BSM**)\\
 +-> **BTF one shot** = gives trigger signal @ BTF and implements BTF status setup for one shot per second or manual shot\\
 +\\
 +__ODOSCOPE setup (**ODO**)__\\
 +-> **DAFNE** = cutoff the DHPTB101 \\
 +-> **DAFNE+BTF** = permits DHPTB101 to pulse\\
 +\\
 +\\
 +
 +**__DAFNE+BTF status__**\\
 +\\
 +**MANUAL SHOT**\\
 +**GTS** -> BTF 1 shot\\
 +**BSM** -> Single shot\\
 +**ODO** -> DAFNE + BTF\\
 +Press RUN BTF button and it fires one pulse\\
 +\\
 +**One shot per second**\\
 +**GTS** -> BTF 1 shot\\
 +**BSM** -> Go Forever and number of impulses = 1\\
 +**ODO** -> DAFNE + BTF\\
 +Press RUN BTF button and it fires at 1 Hz (two pulses per second in DAFNE injection)\\
 +\\
 +** Maximun shot rate**\\
 +**GTS** -> BTF\\
 +**BSM** -> Go forever and number of impluses = 49\\
 +**ODO** -> DAFNE + BTF\\
 +\\
 +
 +==== BTF Signals ====
 +
 +**Q4 signal || BTF word signal** => Syncro word (~8usec before gun pulse) 
 +    Cable panel n.11(inside) SlowControl rack's hall in the BTF Control Room -> output from trg board send to 11(inside)-1
 +\\
 +**BTFTG1**//(user)// signal => Delayed signal (~8usec as before + 6usec delivering time + user delta time) to match the bunch arrival time in btf hall 
 +    Cable panel n.11 in BTF Control Room (near BTF Hall concrete wall) -> output from 11-1, delayed by Stanford C && !D, send to 11-3, from 11(inside)-3 send to a cable TG1BTF in BTF Hall
 +\\ 
 +**BTFTG2**//(user)// signal => Delayed signal (~8usec as before + 6usec delivering time + user delta time) to match the bunch arrival time in btf hall 
 +    Cable panel n.11 in BTF Control Room (near BTF Hall concrete wall) -> output from 11-1, delayed by Stanford A && !B, send to 11-2, from 11(inside)-2 send to a cable TG2BTF in BTF Hall
 +\\
 +**BTFTG0 A/B**//(btf staff)// signal => output from trg board, delayed by Stanford C && !D, send to a cable TG0BTF in BTF Hall
 +**BTFTG0 C/D**//(btf staff)// signal => output from trg board, delayed by Stanford C && !D, send to a cable TG0BTF in BTF Hall
 +\\
 +
 +==Stanford BTF Setup==
 +** TRG EXT Setup **\\
 +THreshold = -0.5V\\
 +Slope = Negative\\
 +Trigger Term = 50Ohm\\
 +\\
 +** GPIB addr **\\
 +User = 14\\
 +\\
 +\\
 +\\
 +A = 15.79 usec\\
 +B = A + 200 nsec (as gate)\\
 +C = 15.79 usec\\
 +D = C + 200 nsec (as gate)\\
 +\\
 +**BTFDAQ Timing Unit**\\
 +DAQ Delay ~200nsec\\
 +\\
 +
 +
 +==== Additional Triggers ====
 +
 +There are additional triggers available for the users:
 +
 +** BTF &&  LINAC state **\\
 +it is possible to select an electron/positron only TTL trigger signal (see the purple signal on the scope screen). 
 +This trigger starts 60 ns after the LINAC trigger.\\
 +{{:strutture:lnf:da:btf:dispositivi:tempi_btf_stato.png?400|}}
 +
 +** BTF && Calorimeter **\\
 +it generates a TTL trigger signal only if there is a LINAC trigger AND a signal in the calorimeter (see the purple signal on the scope screen). This Trigger starts 450 ns after the LINAC trigger.\\
 +{{:strutture:lnf:da:btf:dispositivi:tempi_btfandcalo.png?400|}}
  

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki